Iowa DNR, Land Quality
Tips


About the DNR      DNR News      Contact Us      Site Map   

 
DNR Home
UST/LUST Home
 
Underground Storage Tanks (UST/LUST)
Certified Groundwater Professionals
Groundwater Professional Bulletin Board
Certified Labs & Analytical Methods
Compliance Inspections
Environmental Covenant / Institutional Control
Ethanol
FAQ (Frequently Asked Questions)
Field Office Contacts
Forms/Technical Resources/Manuals
General Information
Iowa Installer Licensing Program
Kaizen Corrective Action Process
Landfarming
Other Links Offsite
Plastic Water Line Survey
Proposed Rules
Staff (LUST/UST)
State UST Fund and Board
UST Administrative Rules
USTfield Projects
UST Inspector's Virtual Classroom
UST System Database
Web Site Map
 
Environmental Services Division Program Areas
Air Quality
Animal Feeding Operations
Contaminated Sites
Emergency Response Unit
Field Services
Legal Services
Waste Management
Water Quality
Water Supply



.Groundwater Professional Bulletin Board

POSTED: 07/25/2002

SITE MONITORING REPORT ERRORS

We are expanding the scope of the work for the firm contracted to review RBCA Tier 1 and 2 Reports to include the review of reclassification Site Monitoring Reports (SMRs). Initially the contractors reviewed 45 SMRs submitted for 27 LUST sites. The following is a summary of common errors contained in the reports. Please check your work to avoid these errors. Tracking the submittal of reclassification SMRs will be an item of emphasis. Please submit the reports as scheduled.

  1. Vapor Sampling Results
  2. Soil source submerged when the vapor sample was collected.
    Vapor sample was collected at the wrong depth.
    Incomplete information (e.g., Static water levels not provided).
    Confirmation vapor sample was not collected.

  3. Tier 2 Report deficiencies were not addressed in the SMR or the method of correcting the deficiencies was inadequate.


  4. Remediation done at the site or the institutional control/restrictive covenant proposal lacks documentation.

  5. Plastic water line replacement not documented.
    Inadequate documentation of overexcavation.
    Documentation of water well ordinances not provided.

  6. Monitoring plan or exit monitoring criteria not met.

  7. Monitoring wells or vapor points listed in the monitoring plan were not sampled.
    Confirmation sampling not conducted.

  8. Site conditions (e.g., Free product was discovered, groundwater maximum increased >20%) warranted a site re-evaluation. Re-evaluation was not conducted.



  9. Soil replacement sampling was inadequate.

  10. Documentation of a submerged soil plume was inadequate.
     
  11. High risk drinking water wells or plastic water lines not sampled.

Contact Elaine Douskey at (515)281-8011 or elaine.douskey@dnr.state.ia.us.

 